Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 127
Filtrar
1.
Microbiol Spectr ; 11(6): e0259923, 2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-37811976

RESUMO

IMPORTANCE: Equine infectious anemia (EIA) has a worldwide distribution and causes significant losses to the equine industry worldwide. A reliable detection method is necessary to control the transmission of EIA virus (EIAV). Currently, most of the available real-time PCR assays, including the qPCR of recommended by WOAH, are developed according to the sequences of European or American EIAV strains; however, the primers and probe sequences have low homology with Asian EIAV strains. To the best of our knowledge, no qPCR method capable of the well detection of Asian EIAV strains, especially Chinese EIAV strains, has been published to date. The development of a sensitive, specific, and rapid qPCR assay for the detection of the EIAV strains is therefore of great importance.


Assuntos
Anemia Infecciosa Equina , Vírus da Anemia Infecciosa Equina , Animais , Cavalos , Vírus da Anemia Infecciosa Equina/genética , Reação em Cadeia da Polimerase em Tempo Real , Anemia Infecciosa Equina/diagnóstico , Primers do DNA/genética
2.
J Vet Diagn Invest ; 35(4): 430-432, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37129383

RESUMO

Using 85 sera collected from horses that had been experimentally infected with equine infectious anemia virus (EIAV) and 200 field sera collected from racehorses in Japan, we compared 4 agar gel immunodiffusion (AGID) kits for serologic detection of EIAV antibodies from Idexx, VMRD, IDvet, and the National Engineering Research Center of Veterinary Biologics, China (NECVB). The positive control lines were sufficiently clear in all kits for evaluation to be made, with slight differences in sharpness: NECVB was the sharpest, followed by VMRD, IDvet, and Idexx. The test results for all 285 samples agreed among the 4 kits, with 62 positives and 223 negatives. The sensitivities and specificities of VMRD, IDvet, and NECVB compared with the Idexx kit were 100%, and the kappa coefficient values between the kits were 1.0 for all combinations. We concluded that the testing capacity of these 4 kits was virtually identical.


Assuntos
Anemia Infecciosa Equina , Doenças dos Cavalos , Vírus da Anemia Infecciosa Equina , Animais , Cavalos , Anemia Infecciosa Equina/diagnóstico , Ágar , Imunodifusão/veterinária , Imunodifusão/métodos , Anticorpos Antivirais , Ensaio de Imunoadsorção Enzimática/veterinária
3.
Appl Microbiol Biotechnol ; 107(10): 3305-3317, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37039847

RESUMO

Equine infectious anemia (EIA) is an important viral disease characterized by persistent infection in equids worldwide. Most EIA cases are life-long virus carriers with low antibody reactions and without the appearance of clinical symptoms. A serological test with high sensitivity and specificity is required to detect inapparent infection. In this study, a B-cell common epitope-based blocking ELISA (bELISA) was developed using a monoclonal antibody together with the EIAV p26 protein labelled with HRP. The test has been evaluated against the standard and with field serum samples globally. This bELISA test can be completed within 75 min, and the sensitivity is higher than those of either the AGID or one commercial cELISA kit. This bELISA assay was 8-16 times more analytically sensitive than AGID, and 2 to 4 times more analytically sensitive than one cELISA kit by testing three sera from the USA, Argentina, and China, respectively. The 353 serum samples from Argentina were tested, in comparison with AGID, the diagnostic sensitivity and specificity of our bELISA assay were 100% (154/154) and 97.0% (193/199), respectively, and the accuracy of the bELISA test was 98.3%. The bELISA test developed in this study is a rapid, sensitive, specific method for the detection of EIAV infection, and could be a promising candidate for use in the monitoring of the EIA epidemic worldwide. KEY POINTS: • A universal epitope-based blocking enzyme-linked immunosorbent assay (bELISA) was developed for detection of antibodies to EIAV. • The bELISA assay can be used to test EIAV serum samples from different regions of the world including North America, South America, Europe, and Asia. • The bELISA assay was evaluated in three different international labs and showed a better performance than other commercial kits.


Assuntos
Anemia Infecciosa Equina , Vírus da Anemia Infecciosa Equina , Cavalos , Animais , Anemia Infecciosa Equina/diagnóstico , Anticorpos Antivirais , Ensaio de Imunoadsorção Enzimática/veterinária , Ensaio de Imunoadsorção Enzimática/métodos , Testes Sorológicos/veterinária , Epitopos de Linfócito B , Sensibilidade e Especificidade
4.
J Virol Methods ; 315: 114704, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36842487

RESUMO

Lentiviruses, including equine infectious anemia virus (EIAV), are considered viral quasispecies because of their intrinsic genetic, structural and phenotypic variability. Immunoenzymatic tests (ELISA) for EIAV reported in the literature were obtained mainly by using the capsid protein p26, which is derived almost exclusively from a single strain (Wyoming), and do not reflect the great potential epitopic variability of the EIAV quasispecies. In this investigation, the GenBank database was exploited in a systematic approach to design a set of representative protein antigens useful for EIAV serodiagnosis. The main bioinformatic tools used were clustering, molecular modelling, epitope predictions and aggregative/ solubility predictions. This approach led to the design of two antigenic proteins, i.e. a full sequence p26 capsid protein and a doublestrain polypeptide derived from the gp45 transmembrane protein fused to Maltose Binding Protein (MBP) that were expressed by recombinant DNA technology starting from synthetic genes, and analyzed by circular dichroism (CD) spectroscopy. Both proteins were used in an indirect ELISA test that can address some of the high variability of EIAV. The novel addition of the gp45 double-strain antigen contributed to enhance the diagnostic sensitivity and could be also useful for immunoblotting application.


Assuntos
Anemia Infecciosa Equina , Vírus da Anemia Infecciosa Equina , Cavalos , Animais , Anemia Infecciosa Equina/diagnóstico , Proteínas do Capsídeo , Vírus da Anemia Infecciosa Equina/genética , Testes Sorológicos/veterinária , Peptídeos
5.
Equine Vet J ; 55(1): 111-121, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35007356

RESUMO

BACKGROUND: Equine infectious anaemia (EIA) is controlled by the identification of seropositive animals. The official diagnostic method is the agar gel immunodiffusion (AGID) test, which detects antibodies against a viral core protein (p26). Although AGID is inexpensive and specific, the report of results takes considerable time and the test has low analytical sensitivity. OBJECTIVE: To validate our in-house indirect ELISAgp90/45 , following the World Organization of Animal Health (OIE) criteria. STUDY DESIGN: Test validation. METHODS: Synthetic peptides gp90 and gp45 were used as antigens in ELISAgp90/45 . Tests used for validation, calibration and linear working operating range, analytical and diagnostic sensitivity and specificity, repeatability and reproducibility were assessed by comparing them with the AGID test and using 1844 equine sera grouped into five different panels. RESULTS: We were able to replace the National References Sera with our Internal Reference Sera. ELISAgp90/45 had acceptable repeatability and reproducibility. Analytical sensitivity of the ELISAgp90/45 was 800 times greater than that of AGID test for positive sera and 400 times greater for weak positive sera. ELISAgp90/45 also showed optimal analytical specificity, since no cross-reactivity was detected with antibodies against other equine viruses. One sample was positive by AGID test and negative by ELISAgp90/45. ELISAgp90/45 was performed using 243 EIA positive and 878 negative equid sera, and showed a diagnostic sensitivity of 99.59% [CI 97.73%-99.99%] and a diagnostic specificity of 90.32% [CI 88.17%-92.19%], compared to AGID test; thus, it was demonstrated to be a robust test. MAIN LIMITATIONS: Samples were derived from naturally infected equid populations showing heterogeneous clinical states: therefore, their status was uncertain and some horses were sampled more than once. The AGID test may not be the most useful gold standard. CONCLUSION: ELISAgp90/45 is a useful tool for the diagnosis of EIAV infection and meets validation requirements established by the OIE.


Assuntos
Anemia Infecciosa Equina , Doenças dos Cavalos , Vírus da Anemia Infecciosa Equina , Cavalos , Animais , Reprodutibilidade dos Testes , Anemia Infecciosa Equina/diagnóstico , Ensaio de Imunoadsorção Enzimática/veterinária , Anticorpos Antivirais , Peptídeos , Imunodifusão/veterinária
6.
Rev. bras. ciênc. vet ; 29(4): 194-198, out./dez. 2022. il.
Artigo em Português | LILACS, VETINDEX | ID: biblio-1427147

RESUMO

A anemia infecciosa equina é uma importante enfermidade que acomete os equídeos em todo o mundo, se apresentando de forma aguda, crônica e assintomática causando grandes prejuízos para a economia tanto para criadores que vivem do trabalho desses animais quantos aos criadores que investem no melhoramento das raças, impedindo o acesso ao mercado tanto nacional quanto internacional. O Ministério da Agricultura, Pecuária e Abastecimento considera o IDGA como teste oficial para diagnóstico dessa enfermidade, porém essa técnica é demorada e muita vez acaba sendo subjetiva, dependendo da experiencia particular de cada Laboratorista. Além de não conseguir detectar animais no início da infecção. Logo, a necessidade de se buscar novas técnicas como o ELISA indireto que aperfeiçoem o tempo de análise dos resultados, facilita a automação e obtém resultados confiáveis. O estudo realizado teve como objetivo padronizar uma técnica de ELISA indireto utilizando uma proteína de envelope viral GP90 como antígeno para diagnóstico da anemia infecciosa equina. Avaliando o desempenho do teste a partir da sensibilidade, especificidade e valores preditivos positivo e negativo. Os valores obtidos foram: 91,11%, 93,33%, 91,11% e 93,33% respectivamente. Concluiu-se que o teste apresenta bom desempenho, além da possibilidade de detectar amimais positivos no início da infecção.


Equine infectious anemia is an important disease that affects horses all over the world, presenting in an acute, chronic and asymptomatic way, causing great damage to the economy, both for breeders who live off the work of these animals and for breeders who invest in the improvement of breeds, preventing access to both national and international markets. The Ministry of Agriculture, Livestock and Food Supply considers AGID to be the official test for diagnosing this disease, but this technique takes time and often ends up being subjective, depending on the particular experience of each laboratory worker. In addition to not being able to detect animals at the beginning of the infection. Therefore, the need to seek new techniques such as indirect ELISA that improve the time of analysis of results, facilitate automation and obtain reliable results. The aim of this study was to standardize an indirect ELISA technique using a GP90 viral envelope protein as an antigen for the diagnosis of equine infectious anemia. Evaluating test performance based on sensitivity, specificity and positive and negative predictive values. The values obtained were 91.11%, 93.33%, 91.11 and 93.33 respectively. It was concluded that the test performs well, in addition to the possibility of detecting positive animals at the beginning of the infection.


Assuntos
Animais , Ensaio de Imunoadsorção Enzimática/veterinária , Proteínas do Envelope Viral/análise , Técnicas Imunoenzimáticas/veterinária , Anemia Infecciosa Equina/diagnóstico , Vírus da Anemia Infecciosa Equina , Cavalos/imunologia , Antígenos Virais/análise
7.
J Equine Vet Sci ; 108: 103795, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34800799

RESUMO

Equine infectious anemia (EIA) is listed by the World Organization for Animal Health (OIE) as one of the equine diseases that must be notified. No effective treatment or vaccine is available. EIA control is based on segregation and euthanasia of positive equids. The disease is caused by the equine infectious anemia virus (EIAV), a member of the genus Lentivirus of the Retroviridae family. Despite the importance of this disease in equids, EIA has been poorly studied in donkeys (Equus asinus). We evaluate the sanitary conditions related to EIAV in donkeys from a shelter of abandoned animals captured on the roads of the Ceará. A total of 124 donkeys were randomly selected, and three horses lived at the same shelter. The animals were clinically evaluated, and a group of the 20 animals was submitted to hematological tests. Three diagnostic tests for EIA were used, agar gel immunodiffusion (AGID), enzyme-linked immunosorbent assay (ELISA) using EIAV recombinant protein gp90 (rgp90) and recombinant protein p26 (rp26) ELISA, and polymerase chain reaction (PCR) for detection of the EIAV tat-gag gene. From the donkeys, only 1 animal was positive using AGID 0.81% (1/124), compared to 21.8% (27/124) in the rgp90 and 10.5% (13/124) in the rp26 ELISA. Proviral DNA was detected by PCR tat-gag in 8.8% (11/124), and phylogenetic analysis confirms that the EIAV sequences of donkeys from the Brazilian Northeast grouped with Pantanal Brazilian sequences. Thus, in light of the results, we conclude that donkeys are carriers of EIAV and could be sources of infection.


Assuntos
Anemia Infecciosa Equina , Vírus da Anemia Infecciosa Equina , Animais , Equidae , Anemia Infecciosa Equina/diagnóstico , Eutanásia Animal , Cavalos , Vírus da Anemia Infecciosa Equina/genética , Filogenia
8.
J Vet Diagn Invest ; 33(4): 758-761, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33797316

RESUMO

Equine infectious anemia (EIA) is a highly infectious disease in members of the Equidae family, caused by equine infectious anemia virus (EIAV). The disease severity ranges from subclinical to acute or chronic, and causes significant economic losses in the equine industry worldwide. Serologic tests for detection of EIAV infection have some concerns given the prolonged seroconversion time. Therefore, molecular methods are needed to improve surveillance programs for this disease. We attempted detection of EIAV in 6 clinical and 42 non-clinical horses in Nuevo Leon State, Mexico, using the agar gel immunodiffusion (AGID) test for antibody detection, and nested and hemi-nested PCR for detection of proviral DNA. We found that 6 of 6, 5 of 6, and 6 of 6 clinical horses were positive by AGID, nested PCR, and hemi-nested PCR, respectively, whereas 0 of 42, 1 of 42, and 9 of 42 non-clinical horses were positive by these tests, respectively. BLAST analysis of the 203-bp 5'-LTR/tat segment of PCR product revealed 83-93% identity with EIAV isolates in GenBank and reference strains from other countries. By phylogenetic analysis, our Mexican samples were grouped in a different clade than other sequences reported worldwide, indicating that the LRT/tat region represents an important target for the detection of non-clinical horses.


Assuntos
Anemia Infecciosa Equina/diagnóstico , Vírus da Anemia Infecciosa Equina/isolamento & purificação , Animais , Anemia Infecciosa Equina/epidemiologia , Anemia Infecciosa Equina/virologia , Feminino , Cavalos , Masculino , México/epidemiologia , Filogenia , Reação em Cadeia da Polimerase/veterinária , Prevalência , Testes Sorológicos/veterinária
9.
J Equine Vet Sci ; 98: 103372, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33663722

RESUMO

Equine infectious anemia is a worldwide distributed disease that affects the Equide family. Commercial effective vaccine is not available, for that reason control of the disease depends on diagnostic tools. To improve the efficiency of the diagnostic program in Cuba, LABIOFAM Group, developed an indirect enzyme-linked immunosorbent assay (ELISA), ELISA kit, to complement the diagnostic system that currently uses the agar gel immunodiffusion (AGID) kit. The ELISA AIE-LAB Kit was evaluated in a Mexican context, compared with the gold standard test Agar gel immunodiffusion, AGID AIE-LABIOFAM, and commercial AGID kit. The analytical sensitivity was determined using serial dilutions twofold of the positive control serum to establish the range of detected antibodies in relation to the cutoff value of the plate (OD 0.300). A precision study was carried out to evaluate repeatability, intermediate precision, and reproducibility by estimating the standard deviation and coefficient of variation. The precision results were satisfactory and the values of the coefficient of variation were considered adequate to guarantee an excellent consistency of the ELISA AIE-LAB. The diagnostic performance of the ELISA AIE-LAB involved the evaluation of specificity, sensitivity, and concordance in comparison with both AGID tests. The diagnostic sensitivity was 100% and the specificity 97.6%, with a very good degree of concordance (Kappa = 0.9). The results suggest that the ELISA AIE-LAB test could be used in Mexico as a diagnostic system for the detection of specific antibodies against the equine infectious anemia virus, as per current international norms.


Assuntos
Anemia Infecciosa Equina , Doenças dos Cavalos , Vírus da Anemia Infecciosa Equina , Animais , Anticorpos Antivirais , Cuba , Ensaio de Imunoadsorção Enzimática/veterinária , Anemia Infecciosa Equina/diagnóstico , Cavalos , México , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
J Virol Methods ; 291: 114101, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33609629

RESUMO

Equine Infectious Anemia is a transmissible viral disease present worldwide, caused by an RNA virus. Viral transmission is mainly mechanical through blood or its products most frequently by blood-sucking arthropods and iatrogenesis as well. OIE recommends Coggins Test as the diagnostic method of choice. Some ELISA tests detect antibodies earlier than the Coggins test, but may produce false-positive results. Currently, new techniques for EIA diagnosis are being developed, such as fluorescence polarization assay which is a simple method for measuring antigen-antibody interaction. The aim of this study was to assess cELISA and Fluorescence Polarization Assay performance for the serological diagnosis of EIA by comparing their results with those of the Coggins test. Tests were performed on 91 workhorses from an endemic zone in the northeast region of Argentina. From the total samples analyzed, 42 tested negative and 49 tested positive in the Coggins test. Same results were obtained using FPA. Using the cELISA, 41 negative results and 50 positive results were obtained. The Receiver Operating Characteristic analysis showed that FPA performance was excellent. Therefore FPA is proposed as an outstanding EIA diagnostic test to be validated in the near future by its simplicity, speed, and objective interpretation of results.


Assuntos
Anemia Infecciosa Equina , Vírus da Anemia Infecciosa Equina , Animais , Anticorpos Antivirais , Argentina/epidemiologia , Ensaio de Imunoadsorção Enzimática , Anemia Infecciosa Equina/diagnóstico , Anemia Infecciosa Equina/epidemiologia , Cavalos , Sensibilidade e Especificidade
11.
J Virol Methods ; 266: 77-88, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30684508

RESUMO

Equine infectious anaemia (EIA) is a blood borne disease that is listed among the notifiable diseases of the World Organisation for Animal Health (OIE). EIA is also regulated by the OIE for the international trading provisions and is generally subject to control programmes. Since 2011, Italy has been conducting a surveillance plan based on a three-tier diagnostic system, using a serological ELISA as screening test, an agar gel immunodiffusion test (AGIDT) as a confirmatory method, and an immunoblot (IB) as an alternative confirmatory assay for discordant results between the first two tests. As for the in-house competitive ELISA (c-ELISA) and the AGIDT, the Italian National Reference Laboratory for EIA (NRL) validated the IB according to the OIE guidelines, employing eight panels containing positive sera, including those from EIA virus (EIAV) proven infected horses, and negative horse, mule and donkey sera collected from different geographical areas. In addition, two international reference image panels were employed for the optimization and the validation of the digital image reading system adopted that allows an impartial measurement of the serum reactivity in the IB assay. The immunological reactivity to EIAV antigens, p26, gp45 and gp90 adsorbed on the IB membrane, determines the serological status of the animal and for EIA, a p26 positive band together with at least one of the other antigen defines a subject as serologically positive for EIAV. For validation, the parameters assessed were threshold values, analytical and diagnostic sensitivity and specificity, repeatability and reproducibility. These parameters were evaluated for each antigen as well as in combination, according to the diagnostic algorithm established above. The validation data defined the IB as having a satisfactory sensitivity, specificity, repeatability and reproducibility for all antigens and species tested. An instrumental recording of the results improves the confidence in using IB as a confirmatory test for EIAV, differently from the AGIDT that is read by an operator. The advantages of using the IB are its higher sensitivity, to that of the AGIDT, which allows an earlier detection of infection that reduces the risk of transmission and therefore the incidence of the EIA, and its higher specificity to that of the ELISA which is based on the discrimination of subjects reacting only against the p26, the antigen used by all ELISAs available, which are not considered as infected by EIAV. In particular, when this assay is used in outbreaks it can detect new cases earlier than the AGIDT, and therefore reduce the restriction period with an economic benefit for the animal owners and the public veterinary sanitary system.


Assuntos
Anticorpos Antivirais/sangue , Monitoramento Epidemiológico/veterinária , Anemia Infecciosa Equina/diagnóstico , Processamento de Imagem Assistida por Computador , Immunoblotting/normas , Vírus da Anemia Infecciosa Equina/imunologia , Animais , Ensaio de Imunoadsorção Enzimática , Anemia Infecciosa Equina/sangue , Cavalos/virologia , Itália , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
J Virol Methods ; 266: 49-57, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30576724

RESUMO

Equine infectious anemia (EIA) is a disease caused by a Lentivirus that is currently controlled exclusively by identification of seropositive animals. In most countries, including Brazil, the official diagnostic test for EIA is the agar gel immunodiffusion test (AGID). Although this assay has a high specificity it can produce false negative reactions or equivocal results due to weak precipitation lines, especially in samples from donkeys, mules or newly infected equids. In this pioneering study, it was used overlapping synthetic peptide pools to map and identify a consensus, widely recognised antibody epitope within env encoding the EIAV envelope proteins. A 20-mer soluble peptide encompassing this epitope (pgp45) was then synthesized and tested in an indirect ELISA test. Using a panel of 859 EIA positive and negative equid serum samples, the pgp45 ELISA had 96.1% concordance, 98.6% sensitivity and 95.6% specificity respectively, when compared to AGID. The sensitivity and specificity of the pgp45 ELISA was also >90% when tested in individual equid species including horses (Equus caballus), donkeys (Equus asinus) and mules (Equus caballus x Equus asinus). Moreover, in a horse experimentally infected with the pathogenic Wyoming EIAV strain viral-specific antibodies were detected at 10 days post-infection (dpi) whereas in AGID no specific antibody was detected until 18 days of experimental infection. This peptide can now be used as an antigen in serological tests, especially for rapid screening of large numbers of equids, where it may contribute significantly in the control of EIA, especially at sites with high populations of donkeys and mules.


Assuntos
Antígenos Virais/imunologia , Ensaio de Imunoadsorção Enzimática/veterinária , Equidae/virologia , Anemia Infecciosa Equina/diagnóstico , Cavalos/virologia , Proteínas do Envelope Viral/imunologia , Animais , Anticorpos Antivirais/sangue , Antígenos Virais/química , Equidae/imunologia , Anemia Infecciosa Equina/imunologia , Reações Falso-Negativas , Cavalos/imunologia , Sensibilidade e Especificidade , Testes Sorológicos/veterinária , Proteínas do Envelope Viral/síntese química
13.
Equine Vet J ; 51(4): 489-494, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30353944

RESUMO

BACKGROUND: Control of equine infectious anaemia (EIA) currently depends on serological diagnosis of infected equids. However, recently infected equids may not produce detectable anti-EIAV antibodies up to 157 days post infection and so present a high transmission risk. Therefore, direct nucleic acid detection methods are urgently needed to improve EIAV surveillance and management programs in counties where the disease is endemic. OBJECTIVES: To evaluate a field-deployable, reverse transcription-insulated isothermal PCR (RT-iiPCR) assay targeting the conserved 5' untranslated region (5' UTR)/exon 1 of the tat gene of EIAV. STUDY DESIGN: The analytical and clinical performance of the newly developed EIAV RT-iiPCR was evaluated by comparison with a EIAV real-time RT-PCR (RT-qPCR) along with the AGID test. METHODS: Analytical sensitivity was determined using in vitro transcribed RNA containing the target area of the 5' UTR/tat gene and samples from two EIAV-positive horses. Specificity was verified using nine common equine viruses. Clinical performance was evaluated by comparison with EIAV RT-qPCR and AGID using samples derived from 196 inapparent EIAV carrier horses. RESULTS: EIAV RT-iiPCR did not react with other commonly encountered equine viruses and had equivalent sensitivity (95% detection limit of eight genome equivalents), with a concordance of 95.41% to conventional EIAV RT-qPCR. However, the RT-qPCR and RT-iiPCR had sensitivities of 43.75 and 50.00%, respectively, when compared to the AGID test. MAIN LIMITATIONS: Low viral loads commonly encountered in inapparent EIAV carriers may limit the diagnostic sensitivity of RT-PCR-based tests. CONCLUSIONS: Although EIAV RT-iiPCR is not sufficiently sensitive to replace the current AGID test, it can augment control efforts by identifying recently exposed or "serologically silent" equids, particularly as the latter often represent a significant transmission risk because of high viral loads. Furthermore, the relatively low cost and field-deployable design enable utilisation of EIAV RT-iiPCR even in remote regions.


Assuntos
Anemia Infecciosa Equina/diagnóstico , Vírus da Anemia Infecciosa Equina/isolamento & purificação , RNA Viral/isolamento & purificação , Reação em Cadeia da Polimerase Via Transcriptase Reversa/veterinária , Animais , Anemia Infecciosa Equina/sangue , Anemia Infecciosa Equina/virologia , Cavalos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Sensibilidade e Especificidade , Testes Sorológicos
14.
Arch Virol ; 163(10): 2871-2875, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29982961

RESUMO

A codon-optimized equine infectious anemia virus p26 gene was fused to a maltose-binding protein (MBP) and expressed in Escherichia coli for use as an antigen in agar gel immunodiffusion (AGID) and enzyme-linked immunosorbent assay (ELISA) for diagnosis of equine infectious anemia. An analysis of analytical sensitivity and specificity showed that the antigen MBP-p26rec reacted positively with a reference World Organization for Animal Health serum and demonstrated no cross-reaction against sera from vaccinated animals in either test. The diagnostic characteristics were evaluated and presented excellent values. The AGIDrec showed 100% sensitivity and specificity, and the ELISArec showed 100% sensitivity and 99.64% specificity. In addition, MBP-p26rec was stabile after three years of storage at 4 °C, maintaining its immunoreactivity.


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Anemia Infecciosa Equina/virologia , Imunodifusão/métodos , Vírus da Anemia Infecciosa Equina/isolamento & purificação , Proteínas Ligantes de Maltose/análise , Proteínas do Core Viral/análise , Animais , Ensaio de Imunoadsorção Enzimática/instrumentação , Anemia Infecciosa Equina/diagnóstico , Anemia Infecciosa Equina/imunologia , Cavalos , Imunodifusão/instrumentação , Vírus da Anemia Infecciosa Equina/genética , Vírus da Anemia Infecciosa Equina/imunologia , Proteínas Ligantes de Maltose/genética , Proteínas Ligantes de Maltose/imunologia , Proteínas do Core Viral/genética , Proteínas do Core Viral/imunologia
15.
J Vet Med Sci ; 80(8): 1245-1247, 2018 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-29899176

RESUMO

This study compared agar gel immunodiffusion (AGID) protocols for diagnosing equine infectious anemia. Two commercial testing kits were used: one following the Japanese Act on Domestic Animal Infectious Diseases Control and one following the World Organisation for Animal Health (OIE) manual. From 651 samples tested, both protocols gave identical results for 647 samples (23 samples tested positive; 624 tested negative). Non-specific reactions were observed in 21 samples testing negative by the Japanese protocol, but none were observed with the OIE protocol. The kappa coefficient value was 0.962, indicating almost perfect agreement between the two protocols. This study found no difference in diagnostic agreement between the two protocols, but the OIE protocol produced non-specific reactions less frequently than the Japanese protocol.


Assuntos
Anticorpos Antivirais/sangue , Anemia Infecciosa Equina/diagnóstico , Imunodifusão/veterinária , Vírus da Anemia Infecciosa Equina/isolamento & purificação , Ágar , Animais , Cavalos , Imunodifusão/métodos , Vírus da Anemia Infecciosa Equina/imunologia , Kit de Reagentes para Diagnóstico/veterinária
16.
J Virol Methods ; 251: 111-117, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28986292

RESUMO

The National Reference Center for equine infectious anemia (EIA) validated a commercial ELISA (Eradikit® EIAV Indirect ELISA, In3diagnostic®, Turin, Italy) employing a chimeric recombinant gag and env peptide for the detection of EIA virus antibodies, following the guidelines of the World Organization for Animal Health. The validation parameters evaluated were: analytical sensitivity (Se) and specificity (Sp); diagnostic Se and Sp; precision, based on repeatability and reproducibility through the estimation of the standard deviation (SD) and the coefficient of variation (CV); accuracy, estimated from a multiple K and relative Sp and Se with respect to those of the agar gel immunodiffusion test (AGIDT). Positive and negative predictive values were also defined. The assay showed a high specificity and a limit of detection of 1.43 log10 major than AGIDT. Diagnostic Se was 100% and Sp was 99.3%, while SD values ranged from 1.58 to 5.01 with a CV between 2.8% and 28.8%. Multiple K was 0.98 and relative Se and Sp were respectively 99.1% and 100%. The assay proved to be robust and to possess a high sensitivity in detecting first antibodies produced at onset of infection as well as high analytic and diagnostic Se and Sp values, confirming it as a serological assay fit for purpose within EIA surveillance programs.


Assuntos
Anticorpos Antivirais/sangue , Antígenos Virais/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Anemia Infecciosa Equina/diagnóstico , Vírus da Anemia Infecciosa Equina/imunologia , Proteínas Recombinantes/imunologia , Testes Sorológicos/métodos , Animais , Antígenos Virais/genética , Produtos do Gene env/genética , Produtos do Gene env/imunologia , Produtos do Gene gag/genética , Produtos do Gene gag/imunologia , Cavalos , Valor Preditivo dos Testes , Proteínas Recombinantes/genética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Can Vet J ; 58(12): 1294-1300, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29203939

RESUMO

This retrospective study was undertaken to estimate i) the surveillance coverage for equine infectious anemia (EIA) based on owner-requested testing, and ii) the incidence of case detection from this surveillance activity to inform a review of Canada's national disease control strategy. Based on sample submissions by accredited veterinarians to laboratories CFIA-approved for EIA testing between 2009 and 2012, the estimated national surveillance coverage was 14% for all years, and 72 cases of EIA were detected. The annual national incidence of EIA detection ranged from 0.03 to 0.08 cases/1000 horses. On average, a greater proportion of the horse population was tested in eastern Canada (32%) than in western Canada (6%, P < 0.0001). The cumulative incidence of EIA detection was higher in western Canada (0.25 cases/1000 horses) than in eastern Canada (0.02 cases/1000 horses, P < 0.0001). This study identified regional differences in owner-requested EIA testing and case detection resulting from this testing activity.


Étude rétrospective des tests demandés par les propriétaires comme surveillance pour l'anémie infectieuse équine au Canada (2009­2012). Cette étude rétrospective a été entreprise afin d'estimer i) la couverture de surveillance pour l'anémie infectieuse équine (AIE) basée sur les tests demandés par les propriétaires et ii) l'incidence de détection des cas à partir de cette activité de surveillance pour documenter un examen de la stratégie nationale de contrôle des maladies du Canada. L'estimation de la couverture nationale de surveillance, basée sur les soumissions d'échantillons par les vétérinaires autorisés aux laboratoires approuvés par l'ACIA pour l'AIE entre 2009 et 2012, était de 14 % pour toutes les années et 72 cas d'AIE ont été détectés. L'incidence nationale annuelle de la détection de l'AIE variait de 0,03 à 0,08 cas/1000 chevaux. En moyenne, une proportion supérieure de la population équine de l'Est du Canada (32 %) subissait des tests par rapport à l'Ouest canadien (6 %, P < 0,0001). L'incidence cumulative de la détection de l'AIE était supérieure dans l'Ouest canadien (0,25 cas/1000 chevaux) par rapport à l'Est du Canada (0,02 cas/1000 chevaux, P < 0,0001). Cette étude a identifié des différences régionales pour les tests de l'AIE demandés par les propriétaires et la détection des cas découlant de cette activité d'épreuve diagnostique.(Traduit par Isabelle Vallières).


Assuntos
Anemia Infecciosa Equina/epidemiologia , Animais , Canadá/epidemiologia , Anemia Infecciosa Equina/diagnóstico , Anemia Infecciosa Equina/prevenção & controle , Cavalos , Incidência , Vigilância da População , Estudos Retrospectivos
18.
Prev Vet Med ; 140: 30-37, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28460747

RESUMO

Equine infectious anemia virus (EIAV) is an important cause of morbidity and mortality throughout the world. Although the virus infects all members of the Equidae the vast majority of studies have been conducted in horses (Equus caballus) with comparatively little information available for other equid species. Brazil has one of the most abundant donkey (E. asinus) populations of any nation although the economic importance of these animals is declining as transportation becomes increasingly mechanized. As a result, considerable numbers of donkeys especially in the Northeast of the country have been released and allowed pursue an almost feral existence. Consequently, this large and growing population constitutes a significant risk as a reservoir for the maintenance and transmission of important equine infectious diseases such as glanders and equine arteritis virus in addition to EIAV. This study examines the prevalence of EIA in a semi-wild donkey population from Mossoró city, in Northeast Brazil, using AGID followed by cELISA, rgp90 ELISA and immunoblot (IB). Serum samples were collected from 367 donkeys without obvious EIA clinical signs. Subsequent testing revealed seropositive rates of 1.6% (6/367) in officially approved AGID tests, 3.3% (12/367) in cELISA and 14.4% (53/367) in the rgp90 ELISA. However, 88.7% (47/53) of the rgp90 ELISA positive samples were almost certainly false reactions because they failed to react with two or more antigens in IB. Consequently, the rpg90 ELISA has a similar sensitivity to AGID with donkey serum samples. Such high false positive rates have not been observed previously with serum samples from horses. Another highly significant finding is that 56.9% (33/58) of the donkey serum samples tested in IB had reactivity to EIAV p26 only. Although this could result from recent infection with the virus, it has been found that in some equids p26 only reactivity persists for extensive periods of time suggesting exposure to antigens possessing cross-reactive determinants or EIAV strains with envelope glycoproteins that are different from any that have been previously characterized and so undetectable by current IB techniques.


Assuntos
Anemia Infecciosa Equina/diagnóstico , Anemia Infecciosa Equina/epidemiologia , Testes Imunológicos/veterinária , Animais , Animais Selvagens , Anticorpos Antivirais/sangue , Antígenos Virais/sangue , Brasil/epidemiologia , Ensaio de Imunoadsorção Enzimática/veterinária , Equidae/sangue , Anemia Infecciosa Equina/sangue , Análise Fatorial , Cavalos , Testes Imunológicos/métodos , Vírus da Anemia Infecciosa Equina/genética , Vírus da Anemia Infecciosa Equina/isolamento & purificação , Prevalência , Sensibilidade e Especificidade
19.
BMC Vet Res ; 13(1): 105, 2017 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-28410613

RESUMO

BACKGROUND: ELISAs are known to have a higher diagnostic sensitivity than the agar gel immunodiffusion (AGID) when employed for serological diagnosis of equine infectious anaemia (EIA). For this purpose, an "in-house" and five commercial ELISAs available in Italy were assessed by the National Reference Centre for EIA for their analytic specificity (Sp); precocity, defined as capability of detecting first antibodies produced during a new infection; precision based on repeatability and reproducibility, estimated from the coefficient of variation (CV); accuracy, estimated from multiple K and relative Sp and sensitivity (Se). Two serum panels, positive for non-equine retroviruses and the most frequent equine viruses, were employed to measure analytic Sp. ELISA precocity was also compared to that of one "in-house" and three commercial AGID kits, employing a panel of sera, collected weekly from horses infected with modified EIA viruses. Precision and accuracy were defined using results of a panel containing positive and negative sera examined in an inter-laboratory trial with the participation of the ten Official Laboratories. Furthermore, a questionnaire was used to assess the appropriateness of each kit for routine use. RESULTS: Analytic Sp was 100%, while the 75th percentile of CVs for positive sera varied from 0.4% to 12.73% for repeatability and from 1.6% to 44.87% for reproducibility. Although CV of the negative serum was constantly high, its outcome was unaltered. Relative Se ranged from 98.2% to 100%, relative Sp was constantly 100% and multiple K ranged from 0.95 to 1. Precocity differed among the assays: three kits detected 4.8% and 42.9% positive samples on 21 days post infection (dpi), all assays detected positive samples on 28 dpi, between 47.6% and 95.2%. Precocity of ELISAs was superior to that of the AGIDs except for two assays. In view of the feedback obtained from the questionnaires, all kits were considered appropriate for routine use. CONCLUSION: All ELISAs having high Se and precocity are preferable as a screening test in EIA surveillance programmes to the AGID tests examined. These two tests can be incorporated in a serial diagnostic pathway to improve the efficacy of a surveillance plan.


Assuntos
Ensaio de Imunoadsorção Enzimática/veterinária , Anemia Infecciosa Equina/diagnóstico , Vírus da Anemia Infecciosa Equina/imunologia , Animais , Anticorpos Antivirais/sangue , Ensaio de Imunoadsorção Enzimática/métodos , Anemia Infecciosa Equina/virologia , Cavalos , Itália , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
J Virol Methods ; 237: 127-131, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27616197

RESUMO

African horse sickness (AHS) and equine infectious anemia (EIA) are both notifiable equid specific diseases that may present similar clinical signs. Considering the increased global movement of horses and equine products over the past decades, together with the socio-economic impact of previous AHS and EIA outbreaks, there is a clear demand for an early discrimination and a strict control of their transmission between enzootic and AHS/EIA-free regions. Currently, the individual control and prevention of AHS or EIA relies on a series of measures, including the restriction of animal movements, vector control, and the use of several laboratory techniques for viral identification, amongst others. Despite being widely employed in surveillance programmes and in the control of animal movements, the available serological assays can only detect AHS- or EIA-specific antibodies individually. In this work, a duplex lateral flow assay (LFA) for simultaneous detection and differentiation of specific antibodies against AHS virus (AHSV) and EIA virus (EIAV) was developed and evaluated with experimental and field serum samples. The duplex LFA was based on the AHSV-VP7 outer core protein and the EIAV-P26 major core protein. The results indicated that the duplex LFA presented a good analytical performance, detecting simultaneously and specifically antibodies against AHSV and EIAV. The initial diagnostic evaluation revealed a good agreement with results from the AHS and EIA tests prescribed by the OIE, and it highlighted the usefulness of the new AHSV/EIAV duplex LFA for an on-field and point-of-care first diagnosis.


Assuntos
Vírus da Doença Equina Africana/imunologia , Doença Equina Africana/diagnóstico , Anticorpos Antivirais/sangue , Ensaio de Imunoadsorção Enzimática/métodos , Anemia Infecciosa Equina/diagnóstico , Vírus da Anemia Infecciosa Equina/imunologia , Doença Equina Africana/imunologia , Animais , Anemia Infecciosa Equina/imunologia , Cavalos , Sistemas Automatizados de Assistência Junto ao Leito , Proteínas do Core Viral/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...